LED Panel Light Sizes: 600x600, 1200x600, 2x2, 1x4

18W RGBW smart led light glass cover round smart led panel light by Bluetooth Wifi

LED panel sizes are quoted as nominal dimensions, not actual ones. A “600 x 600″ panel is 595 x 595 mm and fits a 600 mm grid; a “1200 x 600″ is 1195 x 595 mm and fits two grid modules; a “2 x 2 ft” panel is the imperial name for the first. The cut-out, not the face size, decides whether a recessed panel drops into an existing ceiling — and that is the number most buyers forget to check.

The standard modules

Almost every commercial ceiling is built on one of four modules. Panels are sized 5 mm under the nominal figure so they drop into the grid without binding.

Nominal size Actual face Ceiling module Typical wattage Typical output Best for
600 x 600 / 2 x 2 ft 595 x 595 mm 600 x 600 grid 24–40W 3,400–5,600 lm Offices, classrooms, clinics, retail
1200 x 600 / 2 x 4 ft 1195 x 595 mm Two 600 modules 40–72W 5,600–10,000 lm Open-plan offices, corridors, showrooms
300 x 600 / 1 x 2 ft 295 x 595 mm Half module 18–30W 2,500–4,200 lm Store rooms, toilets, back-of-house
300 x 300 / 1 x 1 ft 295 x 295 mm Quarter module 12–20W 1,500–2,800 lm Fitting rooms, alcoves, feature areas

Small recessed panels are a different family: they are cut into plasterboard rather than laid into a grid, and they are sized by cut-out. Our 15W square panel, for example, is 192 x 192 x 12 mm with a 180 x 180 mm cut-out — a 12 mm deep body that needs almost no ceiling void.

Recessed, surface or suspended

The same panel body can be installed three ways, and the choice changes the effective light distribution as much as the wattage does.

Installation Ceiling requirement Light behaviour Use when
Recessed (grid lay-in) 600 mm T-bar grid, 100 mm+ void Flush, lowest glare, light reaches walls poorly New offices, suspended grid ceilings
Recessed (cut-in) Plasterboard, 60–120 mm void Flush, minimal spill, needs a cut-out Refurbishments, small panels 3–24W
Surface mounted Any flat ceiling Slight downward concentration, visible body Concrete soffits, warehouses, retrofit without void
Suspended Slab or grid, with cables Best upward component, softer shadows High ceilings, feature lighting, offices with 3.5 m+ ceilings

In a 2.7–3 m office, recessed is the default. In a 4–6 m industrial or retail space, suspended panels or high-bay style bodies give better vertical illuminance on rack faces and walls, which is what people actually see.

Wattage and efficacy: what changed in the last five years

Panel efficacy has moved from about 75–90 lm/W for edge-lit bodies to 140 lm/W for backlit bodies, because backlit designs put LEDs directly behind a diffuser instead of firing them into a light guide. That matters commercially: a 40W backlit panel now delivers 5,600 lm, which is the output a 60W edge-lit panel produced a few years ago.

Panel type Efficacy 40W output Notes
Edge-lit (light guide) 75–100 lm/W 3,000–4,000 lm Slim body, lower cost, more sensitive to heat
Backlit (direct) 120–140 lm/W 4,800–5,600 lm Better uniformity, less light loss in the guide
Small recessed (SMD downlight style) 70–90 lm/W n/a Optimised for size and cut-out, not efficacy

Our 595 x 595 backlit panel is a 40W body at 5,600 lm (140 lm/W), 120° beam, Ra ≥ 80, in 3000K / 4000K / 6000K, with a 50,000-hour rating. That is the specification most office and education projects now write into the tender.

How many panels does a room need?

Use the lumen method before reaching for design software. The formula is the same one used for any interior luminaire:

N = (E × A) ÷ (Φ × CU × MF)

where E is target illuminance in lux, A is floor area in m², Φ is lumens per panel, CU is coefficient of utilisation (0.7–0.85 for a typical office) and MF is maintenance factor (0.8).

Worked example — a 5 x 8 m office (40 m²) at 500 lux, using the 40W 5,600 lm panel:

(500 × 40) ÷ (5,600 × 0.8 × 0.8) = 20,000 ÷ 3,584 = 5.6 panels, rounded to six.

Six 595 x 595 panels in a 5 x 8 m room is a 3 x 2 layout, which also happens to suit the ceiling grid. That is the useful part of the calculation: when the answer does not land on a grid-friendly number, adjust the wattage rather than the count, because a 3 x 2 layout with 36W panels will look better than five 40W panels in a staggered arrangement.

For open-plan areas, the target is usually 300–500 lux with UGR below 19 and uniformity above 0.6. Classrooms are often specified at 300–500 lux with the board area at 500 lux.

UGR, CCT and CRI: the three lines that decide whether people complain

  • UGR ≤ 19 for offices and classrooms with screens. A bare diffuser panel at high output can exceed this; specify a micro-prismatic optic or a lower output with more fixtures.
  • 4,000K is the commercial default for offices, schools and clinics; 3,000K for hospitality and residential-feel spaces; 6,000K only for back-of-house, storage and some export markets.
  • Ra ≥ 80 is the minimum for retail and education. For colour-critical retail, ask for Ra ≥ 90, and check the R9 value if reds matter.

Flicker is the fourth line that buyers forget. A panel with poor driver ripple is fine in a store room and unbearable in a room with cameras or with people working under it for eight hours. Ask for the driver’s output ripple figure, not just “flicker free”.

Small panels: where the size is the feature

The 3–24W recessed square and round family exists because ceiling design often drives the lighting rather than the other way around. A 15W square at 192 x 192 mm with a 180 mm cut-out is the standard answer for a hotel corridor, a retail alcove or a bathroom, and the same family runs from 3W to 24W so a single specification covers the whole floor.

Two practical notes: the cut-out tolerance is usually ±2 mm, and the ceiling void needs at least 60 mm for the driver if it is external. On concrete soffits with no void, a surface-mounted panel is the only option — see the surface-mounted versions in our LED panel light range.

Which panel fits which ceiling

Space Size Wattage Target lux Notes
Office, 600 mm grid 595 x 595 36–40W 500 UGR ≤ 19, 4000K, Ra ≥ 80
Open-plan office 1195 x 595 60–72W 400–500 Fewer fixtures, watch uniformity at the perimeter
Classroom 595 x 595 36–40W 300–500 Board lighting often needs a separate row
Corridor / toilet 295 x 595 18–24W 100–200 Consider sensor control
Retail display 595 x 595 or small round 20–40W 300–750 Ra ≥ 90 for colour-critical goods
Hotel / residential alcove 192 x 192 or 240 x 240 6–24W 100–300 Cut-out 180 mm or 220 mm, 12 mm body

If the ceiling is higher than 4 m, a panel is usually the wrong fixture: the light stays near the ceiling and the floor reads dim. In that case look at high bay lighting, or at linear suspended bodies. The comparison between panel-style and batten-style lighting in commercial interiors is covered in LED downlight vs batten light, and the full buying framework is in the LED panel light buying guide.

Frequently asked questions

Is a 600 x 600 LED panel actually 600 mm?

No. A nominal 600 x 600 panel is 595 x 595 mm, so it drops into a 600 mm T-bar grid with clearance. Always confirm the actual face size and cut-out before ordering for a plasterboard ceiling.

What is the difference between 600 x 600 and 2 x 2 ft panels?

They are the same product in different unit systems. 2 x 2 ft equals 610 x 610 mm nominal, and most suppliers ship the 595 x 595 mm body for both descriptions.

How many lumens should a 600 x 600 panel produce?

3,000–4,000 lm for an edge-lit body at 24–36W, and 4,800–5,600 lm for a 40W backlit body. Higher efficacy is worth paying for in rooms with long operating hours.

Can I replace fluorescent troffers with LED panels?

Yes, in most 600 mm grid ceilings the panel is a direct lay-in replacement. Check the driver position, the circuit capacity and whether the existing fitting is switched or dimmed before ordering.

Do LED panels work with dimmers and sensors?

Most do, but the driver decides the protocol. Specify 0–10V, DALI or triac at order stage; adding dimming to a fixed-output driver afterwards is not possible.

Wholesale & OEM supply

LOWCLED supplies backlit and edge-lit panels in 595 x 595, 1195 x 595, 295 x 595 and 295 x 295 mm, plus recessed and surface-mounted small panels from 3W to 24W. Options include 3000K / 4000K / 6000K, Ra ≥ 80 or Ra ≥ 90, 0–10V or DALI dimming, emergency kits and OEM branding. If your project uses a non-standard module, send the ceiling drawing and we will confirm what is available — start at the LED panel light range or request a quotation.

Video: LED FLOOD LIGHT MACHINE GLUING PROCESS - LOWCLED

About this LED panel light

LOWCLED indoor lighting covers LED panel lights, downlights, linear lights, track lights and tube / batten lights for offices, shops, hotels, showrooms and schools. The aluminium housing and diffused optical design give even, low-glare light with UGR<19 for comfortable working conditions.

Panel and downlight series run from 3W to 45W with 100-130 lm/W, IP20-IP65 rating, 3000K / 4000K / 6000K and dimmable or smart WIFI / BLE options. Linear and batten series run from 10W to 80W with linkable connectors, 3-5 years warranty and OEM / ODM service.

Related products from LOWCLED

View all LED panel lights →

Need a quotation, free sample or OEM / ODM service? Write to [email protected] or WhatsApp +86-13590300987 - LOWCLED has been an LED lighting manufacturer in Shenzhen since 2004 and replies within 12 hours.

LED Panel Light Sizes: 600x600, 1200x600, 2x2, 1x4 Related Video:

Video: LED Flood Light IP66 waterproof test - LOWCLED


Well-run equipment, professional sales team, and better after-sales services; We are also a unified big family, everyone stick to the company value "unification, dedication, tolerance" for Led Flood Lamps, Lights For Home, Shoebox Light, Our company will adhere to "Quality first, , perfection forever, people-oriented , technology innovation"business philosophy. Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .

Send your message to us: