LED Stadium Light
What should I check before buying LED stadium flood lights?
LOWCLED supplies LED stadium flood lights in 200W-2000W, up to 160,000 lm for football pitches, arenas, ports and high-mast sites. Every range ships with datasheets, IES photometric files, OEM/ODM branding and a 3-7 year warranty (3-5 years indoor, 5-7 years outdoor). Send the target lux, mounting height and site layout and our engineers return a lighting plan.
Photometric data: measured IES file index · 2027 catalogue
Source: LOWCLED in-house specification tables and datasheets, updated 2026-11.
LOWCLED builds LED stadium lights from 400W to 1600W in the PF series (LL-PF400 to LL-PF1600) plus the PX1000 high-output model, delivering 60,000 lm to 240,000 lm per fixture at 150 lm/W. Input 90-305V AC, optics 15° / 30° / 60° (25° on PX1000), IP65 housing, 10KV surge protection with a 20KV SPD option, Meanwell drivers and PHILIPS LEDs. Five to seven year warranty; CE, RoHS.
On this page: models & output · lux level & fixture count · HID replacement · optics & mast layout · surge, IP & certification · FAQ
LED Stadium Light Manufacturer & Sports Lighting Supplier
Lowcled produces 100W-2000W LED stadium and sports lights up to 160,000 lumens, with modular designs, 30-140 degree beam options, low-glare visors and 277-480V drivers for football fields, arenas, ports and high mast applications.
- Wholesale & project supply: factory-direct stadium light pricing, mixed modular configuration per container, spare driver and module kits for distributors.
- OEM / ODM: private-label branding, custom bracket and aiming accessories, control system integration (DALI, 0-10V, wireless).
- Design support: free Dialux sports lighting layouts, IES files, wind-load and mounting advice.
For stadium tenders and sports lighting wholesale, talk to our project team.
Six models, 60,000 lm to 240,000 lm
The PF series is one housing scaled by module count: 400W and 600W on a two-module body, 800W and 1200W on four, 1600W on eight. All of them run at 150 lm/W, which means the choice between models is the number of fixtures on the mast rather than the technology inside.
The PX1000 is the exception. It is a 1000W single fixture at 150,000 lm with a 25° optic and a 100-277V input, used where a 90-305V PF unit will not fit the electrical design or where the mast already has a 1000W metal halide position to fill.
| Model | Power | Output | Efficacy | Input voltage | Optics | Typical use |
|---|---|---|---|---|---|---|
| LL-PF400 | 400W | 60,000 lm | 150 lm/W | 90-305V AC | 15° / 30° / 60° | training pitch, tennis, small arena |
| LL-PF600 | 600W | 90,000 lm | 150 lm/W | 90-305V AC | 15° / 30° / 60° | amateur match pitch |
| LL-PF800 | 800W | 120,000 lm | 150 lm/W | 90-305V AC | 15° / 30° / 60° | professional pitch, 4-mast layout |
| LL-PF1200 | 1200W | 180,000 lm | 150 lm/W | 90-305V AC | 15° / 30° / 60° | stadium apron, high mast |
| LL-PF1600 | 1600W | 240,000 lm | 150 lm/W | 90-305V AC | 15° / 30° / 60° | large stadium, broadcast class |
| LL-PX1000 | 1000W | 150,000 lm | 150 lm/W | 100-277V AC | 25° | one-for-one 1000W HID replacement |
Output, efficacy, voltage and optics are the published datasheet values. All models: IP65, 10KV surge protection, 20KV SPD available as an option, PF ≥0.9, THD <20%.
How many fixtures for a pitch: work back from the lux level
Stadium lighting is specified as an illuminance on the playing surface, with a uniformity ratio and, for broadcast, a colour-rendering and flicker requirement. A full-size football pitch is 105 x 68 m, or 7,140 m². At a utilisation factor of 0.7 and a light-loss factor of 0.8, the installed lumens needed are target lux x 7,140 ÷ 0.56.
That calculation explains why a training pitch is a four-fixture job and a broadcast pitch is not. It also explains why mast height matters: at 25 m a 15° optic puts the beam on the pitch, while at 15 m the same optic leaves dark bands between masts no matter how many fixtures you add.
| Level | Target lux | Installed lumens needed* | PF400 | PF800 | PF1600 |
|---|---|---|---|---|---|
| Recreational / training | 75 lux | 0.96 M lm | 16 | 8 | 4 |
| Amateur match | 120 lux | 1.53 M lm | 26 | 13 | 7 |
| Professional match | 200 lux | 2.55 M lm | 43 | 22 | 11 |
| Broadcast, fixed cameras | 500 lux | 6.38 M lm | 107 | 54 | 27 |
* Flat pitch, CU 0.7, LLF 0.8, corner masts, no obstruction. Fixture counts are rounded up and exclude emergency or egress lighting. Broadcast installations also need a flicker-free driver and a CRI/R9 check — state the broadcaster standard on the enquiry.
Replacing 1000W and 2000W HID sports lights
Sports floodlighting is where the LED replacement is most obviously worth doing, because the old fittings are on masts and every lamp change costs a crane or a climbing team. A 1000W metal halide sports light draws about 1,100W with the ballast and delivers roughly 65,000 lm when new, less after a season. The PF400 delivers 60,000 lm at 400W and holds it.
The count usually stays the same: a pitch lit by 24 x 1000W metal halide is normally relit with 24 x PF400 on the same masts and the same aiming points, which cuts the load from 26 kW to 9.6 kW and removes the lamp changes.
| Existing sports light | System lumens | LED replacement | Load per fixture | Comment |
|---|---|---|---|---|
| 400W metal halide | 26,000 lm | PF400 (60,000 lm) | 440W to 400W | training pitch, tennis |
| 1000W metal halide | 65,000 lm | PF400 or PX1000 | 1,100W to 400W | same fixture count, same aiming |
| 1500W metal halide | 97,500 lm | PF600 (90,000 lm) | 1,650W to 600W | amateur match pitch |
| 2000W HPS | 130,000 lm | PF800 (120,000 lm) | 2,200W to 800W | professional pitch |
System lumens at 65 lm/W including ballast losses. Where the existing masts are low (under 20 m), the LED count may need to rise to keep uniformity — this is checked in the layout.
Optics and mast layout
A 15° optic throws a narrow beam and is used on tall masts where the fixture is far from the surface; a 60° optic spreads the beam and is used on lower masts and for the corners of the pitch. Most four-mast installations mix the two: 15° on the long axis, 30° or 60° on the short axis, which keeps the light on the pitch instead of spilling into the stands or the sky.
Anti-glare visors and a flat-glass front are available for installations near housing or a road, where the complaint is usually glare rather than illuminance. Ask for the visor at the quotation stage: retrofitting a visor means a second site visit.
Surge, sealing and certification
Sports lighting sits on the tallest structure on the site, which makes it the first thing a lightning surge reaches. The PF series carries 10KV surge protection as standard, and a 20KV SPD can be added for sites with overhead distribution, a history of driver failures after storms, or a utility requirement. This is a real specification difference, not a marketing line: the SPD is a component inside the driver box.
The housing is die-cast aluminium sealed to IP65 with a tempered-glass front, and the driver is a Meanwell unit on this range. Certification is CE, RoHS.
| Attribute | Specification |
|---|---|
| Ingress protection | IP65 |
| Surge protection | 10KV standard; 20KV SPD option |
| Input voltage | 90-305V AC (PF); 100-277V AC (PX1000) |
| Power factor | ≥0.9, THD <20% |
| LED and driver | PHILIPS LED, Meanwell driver |
| Colour temperature | 3000K-6500K; CRI >70 |
| Housing | Die-cast aluminium, tempered glass, IP65 |
| Certification | CE, RoHS |
| Warranty | 5-7 years |
For indoor arenas see the high bay range; for car parks and access roads see shoebox lights. Layout service and IES files on request.
Frequently asked questions
How many lights for a full-size football pitch at 200 lux?
About 2.55 million installed lumens, which is 43 x PF400 or 11 x PF1600 on four corner masts. Real layouts vary with mast height and setback; send the pitch drawing, mast positions and target lux and we return a DIALux layout with the aiming plan.
Can I relight an existing 1000W metal halide pitch without changing the masts?
In most cases yes. A 400W PF unit replaces a 1000W metal halide one for one in fixture count, on the same mast and the same aiming point, while cutting the load to about 40%. Confirm the mast load rating and the existing circuit voltage first.
What is the difference between the 10KV standard and the 20KV SPD option?
Both are surge protection inside the driver circuit; 20KV is a higher clamp for sites with overhead lines, frequent storms or a utility requirement. If your site has had driver failures after lightning, specify 20KV.
Do you provide flicker-free drivers for broadcast?
State the broadcaster or federation standard on the enquiry and we quote the matching driver and confirm the CRI and R9 figures. Broadcast compliance is a driver and calibration question, not only a lumen question.
Is IP65 enough for a stadium?
IP65 is the standard for the PF range and is adequate for outdoor masts. For coastal stadiums add the corrosion-resistant finish option; for covered concourses and indoor arenas the high bay range is usually the better fit.
Do you supply the mast and the aiming plan?
Masts are quoted with the lighting package when requested. The aiming plan, IES files and the lux calculation are supplied with the layout.
Related ranges: LED flood lights for warm-up areas and facades, high bay lights for indoor arenas, shoebox lights for stadium car parks. For the conversion maths behind these tables see the 1000W sports light LED replacement guide.
LED Stadium Light Manufacturer & Sports Lighting Supplier
Lowcled produces 100W-2000W LED stadium and sports lights up to 160,000 lumens, with modular designs, 30-140 degree beam options, low-glare visors and 277-480V drivers for football fields, arenas, ports and high mast applications.
- Wholesale & project supply: factory-direct stadium light pricing, mixed modular configuration per container, spare driver and module kits for distributors.
- OEM / ODM: private-label branding, custom bracket and aiming accessories, control system integration (DALI, 0-10V, wireless).
- Design support: free Dialux sports lighting layouts, IES files, wind-load and mounting advice.
For stadium tenders and sports lighting wholesale, talk to our project team.