Replacing a T8 fluorescent tube with LED is a wiring decision before it is a lighting decision. A 1.2 m 36W fluorescent tube maps to an 18W LED tube at roughly the same light output, but the LED tube will only work after either the ballast is bypassed (most common) or a ballast-compatible tube is chosen to match the exact ballast model. Get the wiring wrong and the tube either flickers, dies within weeks, or creates a shock risk at the lampholders.
T8, T5, T6: what the numbers actually mean
The “T” number is the tube diameter in eighths of an inch. T8 is 8/8 inch (25.4 mm), T5 is 5/8 inch (16 mm), T6 is 6/8 inch (19 mm). Diameter drives the optical design and the socket, not the performance.
| Type | Diameter | Common lengths | Typical LED wattage | Where it is used |
|---|---|---|---|---|
| T5 | 16 mm | 600 / 1200 / 1500 mm | 9 / 18 / 24W | Retail displays, task lighting, slim battens |
| T6 | 19 mm | 600 / 1200 mm | 9 / 18W | High-efficacy linear fittings |
| T8 | 25.4 mm | 600 / 1200 / 1500 mm (2 / 4 / 5 ft) | 9 / 18 / 22W | The default retrofit: offices, stores, warehouses |
In practice T8 dominates retrofit work because the installed base is enormous and the lampholder spacing is standard. T5 is specified in new slim fixtures, where the smaller diameter allows a shallower batten.
Wattage equivalents and lumen output
Fluorescent tubes are rated for initial lumens under laboratory conditions. After two years in a warm ceiling, with dust on the diffuser and a tired ballast, a 36W tube commonly delivers 60–75% of its rating. That is why an 18W LED tube with 1,800–2,200 lm usually reads as brighter than the 36W tube it replaced.
| Length | Fluorescent | Fluorescent lumens | LED replacement | LED lumens |
|---|---|---|---|---|
| 600 mm / 2 ft | 18W T8 | ~1,350 lm | 9W | 1,000–1,200 lm |
| 1200 mm / 4 ft | 36W T8 | ~3,350 lm | 18W | 1,800–2,200 lm |
| 1500 mm / 5 ft | 58W T8 | ~5,200 lm | 22–24W | 2,400–3,200 lm |
| 1200 mm / 4 ft | 28W T5 HO | ~2,900 lm | 14–18W | 1,800–2,400 lm |
The higher-efficacy LED tubes now on the market (170 lm/W class) reach 3,000 lm from 18W, which means a 4 ft fixture can exceed the output of the 36W tube it replaced rather than merely matching it. If the goal is an energy project with a guaranteed lux level, specify the lumen figure, not the wattage.
Ballast bypass: single-ended or double-ended
There are three ways an LED tube can be wired, and mixing them up is the most expensive mistake in a retrofit.
- Ballast bypass, double-ended. The ballast is removed or disconnected, and line and neutral are connected to opposite ends of the fixture. The tube is live at both ends.
- Ballast bypass, single-ended. The ballast is removed, and both line and neutral are fed to the same end of the fixture; the far end is dead. This requires non-shunted lampholders and a clear label on the fixture.
- Ballast compatible (plug-and-play). The existing ballast stays in circuit and the tube is designed to work with specific ballast models. Fastest installation, but only valid if the ballast model is on the tube manufacturer’s compatibility list — and the ballast becomes the weakest link.
| Method | Install effort | Risk | Best for |
|---|---|---|---|
| Double-ended bypass | Medium — rewire both ends, remove ballast | Low if labelled; live ends are the standard | Most commercial retrofits, long-term energy projects |
| Single-ended bypass | Medium — rewiring plus non-shunted holders | Higher if holders are shunted or unlabelled | Fixtures where one end is hard to access |
| Ballast compatible | Low — tube swap only | Ballast failure kills the tube; compatibility list must be checked | Rapid swaps, rented premises, mixed estates |
Two wiring rules apply regardless of method. First, on magnetic-ballast fixtures, the starter must be removed or the circuit bridged; a starter left in circuit will destroy the LED tube. Second, every modified fixture needs a visible label stating that it is LED-only and that the ballast has been removed — this is a code requirement in most jurisdictions and a safety issue for the next electrician.
Where tubes still make sense, and where they do not
Tubes win when the fixture body is sound and only the light source is obsolete: surface battens in car parks, continuous rows in storage areas, back-of-house corridors. They lose when the body itself is the problem.
- Replace the whole fitting if the diffuser is yellowed, the reflector is corroded, or the fixture is not IP-rated for the environment. A new sealed tri-proof batten at 100–140 lm/W will outperform a tube in a tired open channel.
- Replace with linear light where continuous, shadow-free rows matter — see the linear lighting range.
- Keep tubes in fixtures that are already sealed and IP65+, where only the lamp has aged and the housing is still clean.
For sealed fixtures, the selection logic for IP65, IP66, IP69K and Ex versions is worth reading before ordering tubes for a car park or food plant: tri-proof light selection.
Colour, CRI and flicker
Fluorescent tubes were available in a narrow range; LED tubes are available in every colour temperature, which is both an opportunity and a trap. Mixing 4,000K and 6,500K tubes in the same run is visible and looks like a fault, so fix one colour temperature per area and record it on the maintenance schedule.
- 4,000K for offices, corridors, workshops and retail — the safest commercial default.
- 5,000–6,500K for warehouses, cold stores and export markets where a cooler look is expected.
- Ra ≥ 80 minimum; Ra ≥ 90 where produce, textiles or paint colours are judged.
- Flicker: ask for the driver ripple figure. Tubes with visible flicker are unusable under cameras, in workshops with rotating machinery, and in rooms where people read for long periods.
Which LOWCLED tube fits the fixture
Our LED tube range covers the standard retrofit sizes in aluminium-plus-PC and glass bodies:
| Model | Length | Wattage | Body | Notes |
|---|---|---|---|---|
| LL-T8/600-48P-3C-A02 | 600 mm / 2 ft | 9W | Aluminium + PC | 48 x SMD2835, AC 90–265V, PF > 0.9 |
| LL-T8/1200-96P-3C-A02 | 1200 mm / 4 ft | 18W | Aluminium + PC | 96 x SMD2835, the standard 36W fluorescent replacement |
| LL-T8/1500-120P-3C-A02 | 1500 mm / 5 ft | 22W | Aluminium + PC | 120 x SMD2835, replaces 58W T8 |
| Nano T8 series | 600–1500 mm | 9–24W | Slim nano body | Higher efficacy, tighter optical control |
| T5 integrated | 600–1500 mm | 9W / 18W / 24W | Integrated with driver | Linkable, for retail and display runs |
| 170 lm/W T6 / T5 | 1200 / 1500 mm | 14–24W | High-efficacy | For projects with strict watt-per-m² limits |
All series are RoHS compliant, mercury-free, and rated for −20°C to +45°C operation, which covers cold stores and unheated warehouses. If the fixture is sealed and the environment is wet or dusty, a batten is the better answer — see the LED batten range.
Installation checklist
- Photograph the existing wiring before touching it, and record the ballast model if the tubes will be ballast compatible.
- Isolate the circuit at the breaker, not just the switch — fluorescent fixtures are often wired in series with a shared neutral.
- Remove the starter on magnetic-ballast fixtures; bridge the starter socket if the circuit requires continuity.
- Check the lampholders: shunted holders are fine for double-ended bypass, but single-ended wiring needs non-shunted holders.
- Label every modified fixture “LED tube only — ballast bypassed” and note the date.
- Test one fixture in each circuit before committing, then check for flicker at low temperature if the space is refrigerated.
Frequently asked questions
Can I put an LED tube in an existing fluorescent fixture?
Usually yes, but the ballast has to be dealt with. Most LED tubes require the ballast to be bypassed and the starter removed; a minority are ballast compatible, but only with listed ballast models.
What LED tube replaces a 36W T8 fluorescent?
An 18W LED tube at 1,800–2,200 lm is the standard replacement. Higher-efficacy tubes at 170 lm/W can exceed the original output from the same 18W.
Do I need to remove the starter?
On magnetic-ballast fixtures, yes. Leaving the starter in circuit will damage the LED tube. On electronic-ballast fixtures there is no starter, but the ballast still has to be bypassed or matched.
What is the difference between single-ended and double-ended LED tubes?
Double-ended tubes take line and neutral at opposite ends and are live at both ends. Single-ended tubes take both connections at one end and leave the far end dead, which requires non-shunted lampholders.
Are LED tubes dimmable?
Only if the tube is designed for it and the fixture has a compatible dimming driver. Standard retrofit tubes are fixed output; dimming usually means replacing the fixture or using a dimmable batten.
Wholesale & OEM supply
LOWCLED manufactures T8, T5 and T6 LED tubes from 9W to 24W in 600, 1200 and 1500 mm, in aluminium-plus-PC, glass and nano bodies, with 90–265V drivers, PF > 0.9 and optional OEM printing. We supply retrofit programmes for distributors, facility-management contractors and electrical wholesalers, including mixed cartons by length and colour temperature. Start at the LED tube range or request a quotation.
Video: LED flood light test before delivery - LOWCLED
About this LED tube light
LOWCLED outdoor LED flood lights are built for building facades, billboards, gardens, car parks, sports courts and industrial yards. The 4A / 4S / FLU modular series covers 30W to 2000W with 100-120 degree beam angle, tempered glass lens and a die-cast aluminium heat sink that keeps the LED junction temperature low even in summer.
Every fixture passes a 24-hour aging test and an IP66 waterproof test before shipment. With 150 lm/W, 10KV surge protection and 5-7 years warranty options, they replace 250W-2000W metal halide lamps and cut power consumption by around 70%.
Related products from LOWCLED
T8 LED Tube Retrofit: Ballast Bypass and Wattage Chart Related Video:
Video: LED flood light IP66 waterproof test - LOWCLED
We now have several exceptional workers customers good at marketing, QC, and working with types of troublesome trouble during the creation system for Exterior Lighting, Led Bulb For Home, Led Tube Lights, We believe with our consistently excellent service you can get the best performance and cost least goods from us for a long term . We commit to provide better services and create more value to all our customers. Hope we can create a better future together.